HL7 FHIR JP Core ImplementationGuide
1.2.0-dev - ci-build
HL7 FHIR JP Core ImplementationGuide - Local Development build (v1.2.0-dev) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Generated Narrative: Observation jp-observation-electrocardiogram-example-1
JP Core Observation Electrocardiogram NumberOfLeed Extention: 12
JP Core Observation Electrocardiogram Device Interpretation Extention: true
status: Final
category: Procedure
code: EKG Study
subject: 山田 太郎 Male, DoB: 1970-01-01 ( urn:oid:1.2.392.100495.20.3.51.11311234567#00000010)
effective: 2024-10-19 10:00:00+0900
performer: Practitioner 大阪 一郎
interpretation: 正常
component
code: Heart rate.beat-to-beat by EKG
value: 75 {beats}/min
component
code: R-R interval by EKG
value: 800 ms
component
code: P-R Interval
value: 160 ms
component
code: QRS duration
value: 90 ms
component
code: Q-T interval
value: 400 ms
component
code: Q-T interval corrected
value: 420 ss
component
code: P wave axis
value: 60 deg
component
code: QRS axis
value: 30 deg
component
code: R wave amplitude in lead V5
value: 1.2 mV
component
code: S wave amplitude in lead V1
value: 0.9 mV
component
code: R wave amplitude.V5+S wave amplitude.V1
value: 2.1 mV
component
code: T wave axis
value: 45 deg