Generated Sat Dec 28 13:11:07 UTC 2024, FHIR version 4.0.1 for jp-fhir-terminology#1.3.0 (canonical = http://jpfhir.jp/fhir/core/jp-fhir-terminology (history)). See Full QA Report
Quality Checks | |||||||||||||||||||||||||
Publisher Version: | IG Publisher Version: v1.8.4 | ||||||||||||||||||||||||
Publication Code: | n/a . PackageId = jp-fhir-terminology, Canonical = http://jpfhir.jp/fhir/core/jp-fhir-terminology | ||||||||||||||||||||||||
Realm Check for n/a: |
| ||||||||||||||||||||||||
Language Info: | Stated Languages: n/a. IG Resource Lang: n/a. 2 of 199 (1%) of resources have a language. Population Policy: NONE | ||||||||||||||||||||||||
Publication Request: |
| ||||||||||||||||||||||||
Supressed Messages: | 3 Suppressed Issues | ||||||||||||||||||||||||
Dependency Checks: |
| ||||||||||||||||||||||||
Dependent IGs: | no references | ||||||||||||||||||||||||
Global Profiles: | (none declared) | ||||||||||||||||||||||||
Terminology Server(s): | http://tx.fhir.org/r4 (details) | ||||||||||||||||||||||||
HTA Analysis: | Non-HL7 Igs are exempt from terminology dependency analysis | ||||||||||||||||||||||||
R5 Dependencies: | (none) | ||||||||||||||||||||||||
Draft Dependencies: |
| ||||||||||||||||||||||||
Modifier Extensions: | (none) | ||||||||||||||||||||||||
Previous Version Comparison: | Unable to compare with previous version: Unable to find version history at http://jpfhir.jp/fhir/core/jp-fhir-terminology (Problem #1 with package-list.json at http://jpfhir.jp/fhir/core/jp-fhir-terminology: Not Found) | ||||||||||||||||||||||||
IPA Comparison: | n/a | ||||||||||||||||||||||||
IPS Comparison: | n/a | ||||||||||||||||||||||||
Validation Flags: | On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings | ||||||||||||||||||||||||
Summary: | errors = 2, warn = 27, info = 58, broken links = 0 |
output/CodeSystem-actcode-testing.html#/html/body/script at Line 226, column 4 | warning | The <script> containing the javascript '$(document).ready(fu'... is illegal and not allowed on the HL7 cibuild - need to put the script in a .js file in a trusted template if this IG is to build on the HL7 cibuild (also in 1191 other files) |
output/CodeSystem-actcode-testing.html#/html/body/script at Line 266, column 4 | warning | The <script> containing the javascript 'anchors.options.visi'... is illegal and not allowed on the HL7 cibuild - need to put the script in a .js file in a trusted template if this IG is to build on the HL7 cibuild (also in 1191 other files) |
output/CodeSystem-actcode.change.history.html#/html/body/script at Line 193, column 4 | warning | The <script> containing the javascript 'try { var curr'... is illegal and not allowed on the HL7 cibuild - need to put the script in a .js file in a trusted template if this IG is to build on the HL7 cibuild (also in 197 other files) |
1 | warning | The HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide |
2 | warning | An HTML fragment from the set [cross-version-analysis.xhtml, cross-version-analysis-inline.xhtml] is not included anywhere in the produced implementation guide |
3 | warning | An HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide |
4 | warning | The HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide |
Path | Severity | Message |
CodeSystem (l1/c167412) | warning | When HL7 is publishing a resource, the publisher must be provided, and for WG 'ii' it should be 'HL7 International / Imaging Integration' |
CodeSystem (l1/c167412) | warning | The nominated WG 'ii' means that the contact url should be 'http://www.hl7.org/Special/committees/imagemgt' but it was not found |
CodeSystem (l1/c167412) | information | Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG) |
Path | Severity | Message |
CodeSystem (l1/c6760) | error | CodeSystem.publisher: minimum required = 1, but only found 0 (from http://hl7.org/fhir/StructureDefinition/shareablecodesystem|4.0.1) |
Path | Severity | Message |
CodeSystem | warning | When a CodeSystem has content = 'complete', it doesnt make sense for there to be no concepts defined |
Path | Severity | Message |
CodeSystem (l1/c198388) | warning | Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.version is mandatory, but it is not present |
Path | Severity | Message |
CodeSystem | warning | When a CodeSystem has content = 'complete', it doesnt make sense for there to be no concepts defined |
Path | Severity | Message |
CodeSystem | warning | When a CodeSystem has content = 'complete', it doesnt make sense for there to be no concepts defined |
Path | Severity | Message |
CodeSystem | warning | When a CodeSystem has content = 'complete', it doesnt make sense for there to be no concepts defined |
Path | Severity | Message |
CodeSystem.concept[263].designation[0] (l1/c375069) | warning | The designation 'ホリゾン注射液10mg' has no use and is in the same language ('ja'), so is not differentiated from the base display ('ホリゾン注射液10mg・丸石製薬') |
Path | Severity | Message |
CodeSystem | error | Error Rendering Resource: null |
Path | Severity | Message |
ValueSet (l1/c98475) | warning | When HL7 is publishing a resource, the publisher must be provided, and for WG 'ii' it should be 'HL7 International / Imaging Integration' |
ValueSet (l1/c98475) | warning | The nominated WG 'ii' means that the contact url should be 'http://www.hl7.org/Special/committees/imagemgt' but it was not found |
ValueSet.compose.include[0] (l1/c98472) | information | This include has some concepts with displays and some without - check that this is what is intended |
Path | Severity | Message |
ValueSet (l1/c19569) | warning | When HL7 is publishing a resource, the publisher must be provided, and for WG 'ii' it should be 'HL7 International / Imaging Integration' |
ValueSet (l1/c19569) | warning | The nominated WG 'ii' means that the contact url should be 'http://www.hl7.org/Special/committees/imagemgt' but it was not found |
Path | Severity | Message |
ValueSet (l1/c1212) | warning | Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.version is mandatory, but it is not present |
Path | Severity | Message |
ValueSet.where(id = 'jp-medicationcodegs1vs') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:2.51.1.1 (from server |
Path | Severity | Message |
ValueSet.where(id = 'jp-procedure-codes-ichi-vs') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system http://jpfhir.jp/fhir/core/CodeSystem/JP_Undefined_CS (from server |
Path | Severity | Message |
ValueSet.where(id = 'jp-procedure-condition-vs') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system http://jpfhir.jp/fhir/core/CodeSystem/JP_Undefined_CS (from server |
Path | Severity | Message |
ValueSet.where(id = 'jp-procedure-device-action-vs') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system http://jpfhir.jp/fhir/core/CodeSystem/JP_Undefined_CS (from server |
Path | Severity | Message |
ValueSet.where(id = 'jp-procedure-devicekind-vs') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system http://jpfhir.jp/fhir/core/CodeSystem/JP_Undefined_CS (from server |
Path | Severity | Message |
ValueSet.where(id = 'jp-procedure-followup-vs') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system http://jpfhir.jp/fhir/core/CodeSystem/JP_Undefined_CS (from server |
Path | Severity | Message |
ValueSet.where(id = 'jp-procedure-reason-vs') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system http://jpfhir.jp/fhir/core/CodeSystem/JP_Undefined_CS (from server |
Suppressed Messages (Warnings, hints, broken links)
Your Reason Here
Errors sorted by type
fsh-generated/resources/CodeSystem-medis-codesystem-hot9.json | The designation 'ホリゾン注射液10mg' has no use and is in the same language ('ja'), so is not differentiated from the base display ('ホリゾン注射液10mg・丸石製薬') |
fsh-generated/resources/CodeSystem-actcode.json | This property has only a code ('Specializes') and not a URI, so it has no clearly defined meaning in the terminology ecosystem |
fsh-generated/resources/CodeSystem-actcode.json | This property has only a code ('Generalizes') and not a URI, so it has no clearly defined meaning in the terminology ecosystem |
fsh-generated/resources/CodeSystem-jp-imagingstudy-radlexplaybook-coredev-cs.json | Published code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.version is mandatory, but it is not present |
fsh-generated/resources/CodeSystem-dicomuids.json | Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG) |
fsh-generated/resources/CodeSystem-dicomuids.json | When HL7 is publishing a resource, the publisher must be provided, and for WG 'ii' it should be 'HL7 International / Imaging Integration' |
fsh-generated/resources/ValueSet-dicom-sop-classes-vs.json | When HL7 is publishing a resource, the publisher must be provided, and for WG 'ii' it should be 'HL7 International / Imaging Integration' |
fsh-generated/resources/ValueSet-dicom-transfer-syntaxes-vs.json | When HL7 is publishing a resource, the publisher must be provided, and for WG 'ii' it should be 'HL7 International / Imaging Integration' |
fsh-generated/resources/CodeSystem-dicomuids.json | The nominated WG 'ii' means that the contact url should be 'http://www.hl7.org/Special/committees/imagemgt' but it was not found |
fsh-generated/resources/ValueSet-dicom-sop-classes-vs.json | The nominated WG 'ii' means that the contact url should be 'http://www.hl7.org/Special/committees/imagemgt' but it was not found |
fsh-generated/resources/ValueSet-dicom-transfer-syntaxes-vs.json | The nominated WG 'ii' means that the contact url should be 'http://www.hl7.org/Special/committees/imagemgt' but it was not found |
fsh-generated/resources/ValueSet-dicom-sop-classes-vs.json | This include has some concepts with displays and some without - check that this is what is intended |
fsh-generated/resources/ValueSet-jp-allergyintolerance-vs.json | The value set references CodeSystem 'http://jpfhir.jp/fhir/core/CodeSystem/GCM/JP_JfagyMedicationAllergen_CS' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-allergyintolerance-vs.json | The value set references CodeSystem 'http://jpfhir.jp/fhir/core/CodeSystem/YCM/JP_JfagyMedicationAllergen_CS' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-conclusion-codes-jed-vs.json | The value set references CodeSystem 'urn:oid:1.2.392.200270.4.1000.1' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-condition-disease-code-medis-exchange-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-disease-exCode' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-condition-disease-code-medis-record-no-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-disease-keyNumber' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-condition-disease-code-receipt-vs.json | The value set references CodeSystem 'http://jpfhir.jp/fhir/core/mhlw/CodeSystem/masterB-disease' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-condition-disease-modifier-medis-exchange-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-disease-modExCode' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-condition-disease-modifier-medis-record-no-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-disease-modKeyNumber' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-condition-disease-modifier-receipt-vs.json | The value set references CodeSystem 'http://jpfhir.jp/fhir/core/mhlw/CodeSystem/masterZ-disease-modifier' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-diagnosticreportcategory-vs.json | The value set references CodeSystem 'http://loinc.org' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcode-immunization-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-HOT13' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcode-immunization-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-HOT9' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcode-immunization-vs.json | The value set references CodeSystem 'http://capstandard.jp/iyaku.info/CodeSystem/YJ-code' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcode-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-HOT13' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcode-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-HOT7' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcode-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-HOT9' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcode-vs.json | The value set references CodeSystem 'http://capstandard.jp/iyaku.info/CodeSystem/YJ-code' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcodehot13-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-HOT13' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcodehot7-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-HOT7' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcodehot9-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-HOT9' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcodekys-vs.json | The value set references CodeSystem 'http://capstandard.jp/CodeSystem/KikakubetsuYakuzaiSeibun' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcodeyj-excluded-vs.json | The value set references CodeSystem 'http://capstandard.jp/iyaku.info/CodeSystem/YJ-code-excluded' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationcodeyj-vs.json | The value set references CodeSystem 'http://capstandard.jp/iyaku.info/CodeSystem/YJ-code' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-medicationusagejami-vs.json | The value set references CodeSystem 'http://jami.jp/CodeSystem/MedicationUsage' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-microbiology-category-laboratory-vs.json | The value set references CodeSystem 'http://loinc.org' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-observationlabresultcode-vs.json | The value set references CodeSystem 'http://medis.or.jp/CodeSystem/master-JLAC10-17digits' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-procedurecodesdental-vs.json | The value set references CodeSystem 'http://jpfhir.jp/fhir/core/CodeSystem/JP_ProcedureCodesDental_CS' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-procedurecodesmedical-vs.json | The value set references CodeSystem 'http://jpfhir.jp/fhir/core/CodeSystem/JP_ProcedureCodesMedical_CS' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-procedurecodesnurse-vs.json | The value set references CodeSystem 'urn:oid:1.2.392.200119.4.701' which has status 'fragment' |
fsh-generated/resources/ValueSet-jp-reason-codes-jed-vs.json | The value set references CodeSystem 'urn:oid:1.2.392.200270.4.1000.1' which has status 'fragment' |
fsh-generated/resources/ValueSet-mhlw-valueset-icd10-2013-jp.json | The value set references CodeSystem 'http://jpfhir.jp/fhir/core/mhlw/CodeSystem/ICD10-2013-full' which has status 'fragment' |
fsh-generated/resources/CodeSystem-ex-diagnosistype.json | CodeSystem.publisher: minimum required = 1, but only found 0 (from http://hl7.org/fhir/StructureDefinition/shareablecodesystem|4.0.1) |