HL7 FHIR JP Core ImplementationGuide
1.3.0-dev - ci-build
HL7 FHIR JP Core ImplementationGuide - Local Development build (v1.3.0-dev) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| 項目 | 内容 |
| 定義URL | http://jpfhir.jp/fhir/core/ValueSet/JP_DICOMModality_VS |
| Version | 1.3.0-dev |
| Name | JP_DICOMModality_VS |
| Title | JP Core DICOM Modality ValueSet |
| Status | Active ( 2024-12-30 ) |
| Copyright | DICOM® is the registered trademark of the National Electrical Manufacturers Association for its Standards publications relating to digital communications of medical information. |
放射線モダリテに対する 値セット
References
http://dicom.nema.org/resources/ontology/DCM version 📦01| Code | Display | Definition |
| AR | Autorefraction | Autorefraction device |
| AU | Basic Voice Audio | Audio object |
| BDUS | Ultrasound Bone Densitometry | Ultrasound Bone Densitometry (modality) |
| BI | Biomagnetic Imaging | Biomagnetic imaging device |
| BMD | Bone Mineral Densitometry | Bone Mineral Densitometry by X-Ray (modality), including dual-energy X-Ray absorptiometry (DXA) and morphometric X-Ray absorptiometry (MXA) |
| CR | Computed Radiography | Computed Radiography device |
| CT | Computed Tomography | Computed Tomography device |
| DG | Diaphanography | Diaphanography device |
| DX | Digital Radiography | Digital Radiography device |
| ECG | Electrocardiography | Electrocardiography device |
| EPS | Cardiac Electrophysiology | Cardiac Electrophysiology device |
| ES | Endoscopy | Endoscopy device |
| GM | General Microscopy | General Microscopy device |
| HC | Hard Copy | Hard Copy |
| HD | Hemodynamic Waveform | Hemodynamic Waveform acquisition device |
| IO | Intra-oral Radiography | Intra-oral Radiography device |
| IVOCT | Intravascular Optical Coherence Tomography | An acquisition device, process or method that performs intravascular optical coherence tomography |
| IVUS | Intravascular Ultrasound | Intravascular Ultrasound device |
| KER | Keratometry | Keratometry device |
| KO | Key Object Selection | Key Object Selection object |
| LEN | Lensometry | Lensometry device |
| LS | Laser Scan | Laser surface scan device |
| MG | Mammography | Mammography device |
| MR | Magnetic Resonance | Magnetic Resonance device |
| NM | Nuclear Medicine | Nuclear Medicine device |
| OAM | Ophthalmic Axial Measurements | Measurements of the axial length of the eye, which are done by various devices |
| OCT | Optical Coherence Tomography | Modality device that uses an interferometric, non-invasive optical tomographic technique to image 2D slices and 3D volumes of tissue using visible and near visible frequencies |
| OP | Ophthalmic Photography | Ophthalmic photography modality |
| OPM | Ophthalmic Mapping | Modality device that measures corneal topography, corneal or retinal thickness, and other similar parameters that are typically displayed as maps |
| OPT | Ophthalmic Tomography | Tomography of the eye acquired by a modality that is based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded |
| OPV | Ophthalmic Visual Field | Modality device that measures visual fields and perform visual perimetry |
| OSS | Optical Surface Scanner | An acquisition device, process or method that performs optical surface scanning |
| OT | Other | Other Modality device |
| PR | Presentation State | Presentation State object |
| PT | Positron emission tomography | Positron emission tomography (PET) device |
| PX | Panoramic X-Ray | Panoramic X-Ray device |
| REG | Registration | Registration |
| RF | Radiofluoroscopy | Radiofluoroscopy device |
| RG | Radiographic imaging | Radiographic imaging (conventional film/screen) |
| RTDOSE | RT Dose | Radiotherapy Dose |
| RTIMAGE | RT Image | Radiotherapy Imaging device; includes portal imaging |
| RTPLAN | RT Plan | Radiotherapy Plan |
| RTRECORD | RT Treatment Record | Radiotherapy Treatment Record |
| RTSTRUCT | RT Structure Set | Radiotherapy Structure Set |
| SEG | Segmentation | Segmentation |
| SM | Slide Microscopy | Slide Microscopy |
| SMR | Stereometric Relationship | Stereometric image pairing modality |
| SR | Structured Report Document | Structured Report Document |
| SRF | Subjective Refraction | Subjective Refraction device |
| TG | Thermography | Thermography device |
| US | Ultrasound | Ultrasound device |
| VA | Visual Acuity | Visual Acuity device |
| XA | X-Ray Angiography | X-Ray Angiography device |
| XC | External-camera Photography | External-camera Photography device |
Expansion performed internally based on codesystem DICOM Controlled Terminology Definitions v01 (CodeSystem)
This value set contains 54 concepts
| System | Code | Display (ja) | Definition | JSON | XML |
http://dicom.nema.org/resources/ontology/DCM | AR | Autorefraction device | |||
http://dicom.nema.org/resources/ontology/DCM | AU | Audio object | |||
http://dicom.nema.org/resources/ontology/DCM | BDUS | Ultrasound Bone Densitometry (modality) | |||
http://dicom.nema.org/resources/ontology/DCM | BI | Biomagnetic imaging device | |||
http://dicom.nema.org/resources/ontology/DCM | BMD | Bone Mineral Densitometry by X-Ray (modality), including dual-energy X-Ray absorptiometry (DXA) and morphometric X-Ray absorptiometry (MXA) | |||
http://dicom.nema.org/resources/ontology/DCM | CR | Computed Radiography device | |||
http://dicom.nema.org/resources/ontology/DCM | CT | Computed Tomography device | |||
http://dicom.nema.org/resources/ontology/DCM | DG | Diaphanography device | |||
http://dicom.nema.org/resources/ontology/DCM | DX | Digital Radiography device | |||
http://dicom.nema.org/resources/ontology/DCM | ECG | Electrocardiography device | |||
http://dicom.nema.org/resources/ontology/DCM | EPS | Cardiac Electrophysiology device | |||
http://dicom.nema.org/resources/ontology/DCM | ES | Endoscopy device | |||
http://dicom.nema.org/resources/ontology/DCM | GM | General Microscopy device | |||
http://dicom.nema.org/resources/ontology/DCM | HC | Hard Copy | |||
http://dicom.nema.org/resources/ontology/DCM | HD | Hemodynamic Waveform acquisition device | |||
http://dicom.nema.org/resources/ontology/DCM | IO | Intra-oral Radiography device | |||
http://dicom.nema.org/resources/ontology/DCM | IVOCT | An acquisition device, process or method that performs intravascular optical coherence tomography | |||
http://dicom.nema.org/resources/ontology/DCM | IVUS | Intravascular Ultrasound device | |||
http://dicom.nema.org/resources/ontology/DCM | KER | Keratometry device | |||
http://dicom.nema.org/resources/ontology/DCM | KO | Key Object Selection object | |||
http://dicom.nema.org/resources/ontology/DCM | LEN | Lensometry device | |||
http://dicom.nema.org/resources/ontology/DCM | LS | Laser surface scan device | |||
http://dicom.nema.org/resources/ontology/DCM | MG | Mammography device | |||
http://dicom.nema.org/resources/ontology/DCM | MR | Magnetic Resonance device | |||
http://dicom.nema.org/resources/ontology/DCM | NM | Nuclear Medicine device | |||
http://dicom.nema.org/resources/ontology/DCM | OAM | Measurements of the axial length of the eye, which are done by various devices | |||
http://dicom.nema.org/resources/ontology/DCM | OCT | Modality device that uses an interferometric, non-invasive optical tomographic technique to image 2D slices and 3D volumes of tissue using visible and near visible frequencies | |||
http://dicom.nema.org/resources/ontology/DCM | OP | Ophthalmic photography modality | |||
http://dicom.nema.org/resources/ontology/DCM | OPM | Modality device that measures corneal topography, corneal or retinal thickness, and other similar parameters that are typically displayed as maps | |||
http://dicom.nema.org/resources/ontology/DCM | OPT | Tomography of the eye acquired by a modality that is based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded | |||
http://dicom.nema.org/resources/ontology/DCM | OPV | Modality device that measures visual fields and perform visual perimetry | |||
http://dicom.nema.org/resources/ontology/DCM | OSS | An acquisition device, process or method that performs optical surface scanning | |||
http://dicom.nema.org/resources/ontology/DCM | OT | Other Modality device | |||
http://dicom.nema.org/resources/ontology/DCM | PR | Presentation State object | |||
http://dicom.nema.org/resources/ontology/DCM | PT | Positron emission tomography (PET) device | |||
http://dicom.nema.org/resources/ontology/DCM | PX | Panoramic X-Ray device | |||
http://dicom.nema.org/resources/ontology/DCM | REG | Registration | |||
http://dicom.nema.org/resources/ontology/DCM | RF | Radiofluoroscopy device | |||
http://dicom.nema.org/resources/ontology/DCM | RG | Radiographic imaging (conventional film/screen) | |||
http://dicom.nema.org/resources/ontology/DCM | RTDOSE | Radiotherapy Dose | |||
http://dicom.nema.org/resources/ontology/DCM | RTIMAGE | Radiotherapy Imaging device; includes portal imaging | |||
http://dicom.nema.org/resources/ontology/DCM | RTPLAN | Radiotherapy Plan | |||
http://dicom.nema.org/resources/ontology/DCM | RTRECORD | Radiotherapy Treatment Record | |||
http://dicom.nema.org/resources/ontology/DCM | RTSTRUCT | Radiotherapy Structure Set | |||
http://dicom.nema.org/resources/ontology/DCM | SEG | Segmentation | |||
http://dicom.nema.org/resources/ontology/DCM | SM | Slide Microscopy | |||
http://dicom.nema.org/resources/ontology/DCM | SMR | Stereometric image pairing modality | |||
http://dicom.nema.org/resources/ontology/DCM | SR | Structured Report Document | |||
http://dicom.nema.org/resources/ontology/DCM | SRF | Subjective Refraction device | |||
http://dicom.nema.org/resources/ontology/DCM | TG | Thermography device | |||
http://dicom.nema.org/resources/ontology/DCM | US | Ultrasound device | |||
http://dicom.nema.org/resources/ontology/DCM | VA | Visual Acuity device | |||
http://dicom.nema.org/resources/ontology/DCM | XA | X-Ray Angiography device | |||
http://dicom.nema.org/resources/ontology/DCM | XC | External-camera Photography device |
Explanation of the columns that may appear on this page:
| Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
| System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
| Code | The code (used as the code in the resource instance) |
| Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
| Definition | An explanation of the meaning of the concept |
| Comments | Additional notes about how to use the code |